{"product_id":"dramm-misttime-temperature-probe","title":"Dramm - MistTime Temperature Probe","description":"\u003ch2\u003eMistTime Temperature Probe\u003c\/h2\u003e\u003cp\u003eA MistTime misting controller runs on time out of the box; the temperature probe is what lets it run on temperature. With a probe on the sensor input, a valve can be set to hold off until the air passes a set point and then tighten its cycle as the temperature keeps climbing, so the same output behaves as a propagation mist controller in the morning and a cooling controller in the afternoon. The two probes here are not interchangeable: resistance is matched to the controller generation, and the wrong one reads false or trips a sensor fault alarm. Check which MistTime is on the wall before ordering.\u003c\/p\u003e\u003cp\u003eOrder by controller, not by price, because both probes carry the same price and only one will read correctly on your unit. MT10-TP is the 100 to 3000 ohm probe for the MistTime 10, the current ten-output controller. MTRC-TP is the 1000 ohm probe for the earlier MistTime 02 and MistTime 08 controllers. The MistTime 10 has a single temperature input, so one probe serves every valve on the controller no matter how many are wired; site it out in the crop canopy in the zone you want the temperature logic to follow, not at the panel, and run it back on shielded cable with the shield landed on the controller ground and the run kept away from the valve wiring.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 ohm (MTRC-TP) or 100 to 3000 ohm (MT10-TP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMistTime 02 and MistTime 08 (MTRC-TP) or MistTime 10 (MT10-TP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterchangeable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo; the two resistances are not cross-compatible between controller generations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional temperature input; starts a mist cycle above a set point and shortens the cycle as temperature rises\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature inputs on the controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne, shared by all valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShielded cable, 0.8 sq mm minimum, shield landed on the controller ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone; the sensor is not user-calibratable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSold as\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eConfigurations\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eController\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMistTime 10 - 100 to 3000 ohm\u003c\/td\u003e\n\u003ctd\u003eMT10-TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMistTime 02 and 08 - 1000 ohm\u003c\/td\u003e\n\u003ctd\u003eMTRC-TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGives a MistTime temperature control on top of the time-based cycling it does as standard\u003c\/li\u003e\n\u003cli\u003eStarts a valve once the air passes a set point, then shortens the cycle time as temperature climbs through the proportional band\u003c\/li\u003e\n\u003cli\u003eOne input serves the whole controller while each valve stays independently set to time, temperature, or time and temperature\u003c\/li\u003e\n\u003cli\u003eMT10-TP is the 100 to 3000 ohm probe for the MistTime 10\u003c\/li\u003e\n\u003cli\u003eMTRC-TP is the 1000 ohm probe for the earlier MistTime 02 and MistTime 08\u003c\/li\u003e\n\u003cli\u003eThe controller raises a sensor fault alarm if the probe or its wiring fails, so a dead sensor does not silently stop the mist\u003c\/li\u003e\n\u003cli\u003eNothing to calibrate and nothing to set on the probe itself\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIdeal Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePropagation mist that has to speed up on bright, hot afternoons and back off overnight\u003c\/li\u003e\n\u003cli\u003eEvaporative cooling zones started by air temperature rather than by the clock\u003c\/li\u003e\n\u003cli\u003eMixed houses where some valves run on time and others follow temperature from the same controller\u003c\/li\u003e\n\u003cli\u003eReplacing a probe damaged by carts, hose or a chemical application\u003c\/li\u003e\n\u003cli\u003eAdding temperature capability to a MistTime that was commissioned as a time-only controller\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eThe probe plugs into the Dramm MistTime misting controller, MT-10, driving Dramm solenoid valves on JetFog nozzles or overhead mist lines.\u003c\/em\u003e\u003c\/p\u003e","brand":"Dramm","offers":[{"title":"MistTime 10 - 100 to 3000 ohm","offer_id":52800840925495,"sku":"MT10-TP","price":89.6,"currency_code":"USD","in_stock":true},{"title":"MistTime 02 and 08 - 1000 ohm","offer_id":52800840958263,"sku":"MTRC-TP","price":89.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/0341\/5863\/files\/dramm-brand-placeholder_c62b7c9c-c689-427d-988c-8781419e87b1.png?v=1786400658","url":"https:\/\/www.blacklabelsupply.io\/products\/dramm-misttime-temperature-probe","provider":"BLACK LABEL","version":"1.0","type":"link"}