{"product_id":"dramm-misttime-misting-controller","title":"Dramm - MistTime Misting Controller","description":"\u003ch2\u003eMistTime Misting Controller\u003c\/h2\u003e\u003cp\u003eMistTime is a 10 output mist and pulse irrigation controller in a NEMA 4 rated PVC housing. Every output is programmed independently on its own duration and interval, so one unit can run a propagation mist bench, a pulse irrigation zone and a mist cooling circuit at the same time. Duration goes from 1 second to 60 minutes and interval from 1 minute to 12 hours, which is the whole range from a two second mist shot to an hourly irrigation.\u003c\/p\u003e\u003cp\u003eThis is the 10 output model, so the sizing question is how many circuits you actually have and whether you need the pump pre-start. The last output can be converted to a pump pre-start with a variable lead time, so a well, pressure or injector pump is already running before any valve opens - use that and you have 9 valve circuits rather than 10. It is worth choosing MistTime over Dramm's other controllers specifically for the second-scale timing: the Villa controller has a 1 minute minimum cycle and will not do mist, and the ii ri drives a single valve. Outputs are 24 VAC, which is what the Dramm Pro-Series solenoid valves expect, with a maximum output load of 6 A.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 independently programmed valve circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 v \/ 230 v AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum output load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCycle duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 second to 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCycle interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 minute to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump pre-start\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe last output converts to a pump pre-start with variable pre-start time, leaving 9 valve circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 4 rated PVC housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTC 3000 ohm (MT10-TP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French or Dutch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTen independent cycles on one unit - mist, pulse irrigation and mist cooling side by side\u003c\/li\u003e\n\u003cli\u003eOne second minimum duration, which is what separates a mist controller from an irrigation controller\u003c\/li\u003e\n\u003cli\u003eFour modes: around the clock, between set hours, above a set temperature, or time and temperature together\u003c\/li\u003e\n\u003cli\u003eMist curve builds up to six time buckets so the cycle changes through the day\u003c\/li\u003e\n\u003cli\u003eManual cycle can be run at any time and the controller returns to the last program straight after\u003c\/li\u003e\n\u003cli\u003ePump pre-start output brings a well or injector pump up before a valve opens\u003c\/li\u003e\n\u003cli\u003eNEMA 4 rated PVC housing for a wet head house\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIdeal Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePropagation mist benches where duration is measured in seconds\u003c\/li\u003e\n\u003cli\u003ePulse irrigation of container crops in short repeated shots\u003c\/li\u003e\n\u003cli\u003eTemperature-triggered mist cooling\u003c\/li\u003e\n\u003cli\u003eMulti-zone mist houses needing a different cycle per bench\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eDrives Dramm Pro-Series 24 VAC solenoid valves, takes the MT10-TP temperature sensor for temperature-triggered cycles, and Dramm publishes the manual in English, Spanish and French.\u003c\/em\u003e\u003c\/p\u003e","brand":"Dramm","offers":[{"title":"10 Output","offer_id":52800280985911,"sku":"MT-10","price":1584.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/0341\/5863\/files\/fs.Dramm-MistTime-10-controller_d2e774a5-b1f3-4a75-bdc3-960db25ced0c.png?v=1786404469","url":"https:\/\/www.blacklabelsupply.io\/products\/dramm-misttime-misting-controller","provider":"BLACK LABEL","version":"1.0","type":"link"}