{"product_id":"dab-tesla-4cbus-well-pump-control-box","title":"Dab Pumps - TESLA Well Pump Control Box for 3-Wire Submersible Motors","description":"\u003ch2\u003eDAB TESLA Well Pump Control Box for 3-Wire Submersible Motors\u003c\/h2\u003e\u003cp\u003eThe TESLA 4CBUS is the control box for DAB TESLA 4 in three wire single phase submersible motors, covering 0.5 HP through 5 HP. It houses the start capacitor, the run capacitor where fitted, the starting relay and the overload protector that a three wire motor needs in order to start and to be protected in service. The enclosure is metal with a protective painted coating and comes with three knockouts for conduit entry.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eA 3-wire single phase submersible motor cannot run without a matching control box.\u003c\/strong\u003e Unlike a three phase motor, a single phase motor produces only a fraction of its rated torque at startup, so the starting components it needs are placed outside the motor in the control box. DAB states plainly in the TESLA installation manual: the pump will not operate without this control box, and operation without the control box will burn out the motor. The box must also match the motor horsepower and voltage, because the capacitors and overload inside it are sized to that motor.\u003c\/p\u003e\u003cp\u003eTwo construction types are offered. The Small Type covers 0.5 HP to 1 HP and is capacitor start (CSIR); it is built in the Basic configuration only. The Large Type covers 1.5 HP to 5 HP and is capacitor start capacitor run (CSCR); it is offered in both Basic and Plus. The Plus boxes contain magnetic line contactors carefully matched to the motor rating, eliminating the need for external line contactors. Capacitor values are identical between Basic and Plus at every horsepower, so the choice is purely whether the contactor is built in or wired externally. Boxes are NEMA 3R rated for indoor or outdoor mounting and must be mounted vertically with the top side up so the starting relay works correctly.\u003c\/p\u003e\u003ch3\u003eAvailable Models\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e0.5 HP - 115V - Basic: 0.5 HP, 115V, capacitor start (CSIR) Small Type. 12.6 A maximum, start capacitor 250 to 300 uF at 125V. Branch protection 15 A Class RK1, RK5 or J fuses.\u003c\/li\u003e\n\u003cli\u003e0.5 HP - 230V - Basic: 0.5 HP, 230V, capacitor start (CSIR) Small Type. 6.8 A maximum, start capacitor 59 to 71 uF at 250V. Branch protection 10 A Class RK1, RK5 or J fuses.\u003c\/li\u003e\n\u003cli\u003e0.75 HP - 230V - Basic: 0.75 HP, 230V, capacitor start (CSIR) Small Type. 8.5 A maximum, start capacitor 86 to 103 uF at 250V. Branch protection 10 A Class RK1, RK5 or J fuses.\u003c\/li\u003e\n\u003cli\u003e1 HP - 230V - Basic: 1 HP, 230V, capacitor start (CSIR) Small Type. 9.8 A maximum, start capacitor 105 to 126 uF at 250V. Branch protection 15 A Class RK1, RK5 or J fuses.\u003c\/li\u003e\n\u003cli\u003e1.5 HP - 230V - Basic: 1.5 HP, 230V, capacitor start capacitor run (CSCR) Large Type, Basic. 12 A maximum, start capacitor 105 to 126 uF at 250V, run capacitor 10 uF at 370V. Branch protection 15 A.\u003c\/li\u003e\n\u003cli\u003e2 HP - 230V - Basic: 2 HP, 230V, capacitor start capacitor run (CSCR) Large Type, Basic. 12.3 A maximum, start capacitor 105 to 126 uF at 250V, run capacitor 20 uF at 370V. Branch protection 15 A.\u003c\/li\u003e\n\u003cli\u003e3 HP - 230V - Basic: 3 HP, 230V, capacitor start capacitor run (CSCR) Large Type, Basic. 16.2 A maximum, start capacitor 208 to 250 uF at 250V, run capacitor 45 uF at 370V. Branch protection 20 A.\u003c\/li\u003e\n\u003cli\u003e5 HP - 230V - Basic: 5 HP, 230V, capacitor start capacitor run (CSCR) Large Type, Basic. 25.5 A maximum, start capacitor 270 to 324 uF at 250V, run capacitors 2 x 40 uF at 370V. Branch protection 30 A.\u003c\/li\u003e\n\u003cli\u003e1.5 HP - 230V - Plus: 1.5 HP, 230V, CSCR Large Type, Plus. Same capacitors and 12 A rating as the 1.5 HP Basic, with a factory matched magnetic line contactor added so no external contactor is needed.\u003c\/li\u003e\n\u003cli\u003e2 HP - 230V - Plus: 2 HP, 230V, CSCR Large Type, Plus. Same capacitors and 12.3 A rating as the 2 HP Basic, with a factory matched magnetic line contactor added so no external contactor is needed.\u003c\/li\u003e\n\u003cli\u003e3 HP - 230V - Plus: 3 HP, 230V, CSCR Large Type, Plus. Same capacitors and 16.2 A rating as the 3 HP Basic, with a factory matched magnetic line contactor added so no external contactor is needed.\u003c\/li\u003e\n\u003cli\u003e5 HP - 230V - Plus: 5 HP, 230V, CSCR Large Type, Plus. Same capacitors and 25.5 A rating as the 5 HP Basic, with a factory matched magnetic line contactor added so no external contactor is needed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApplication: DAB TESLA 4 in three wire single phase submersible motors, 4GG and 4GX series\u003c\/li\u003e\n\u003cli\u003eHorsepower Range: 0.5 HP to 5 HP\u003c\/li\u003e\n\u003cli\u003eVoltage: 115V on the 0.5 HP 115V model, 230V on all other models\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003ePhase: Single phase\u003c\/li\u003e\n\u003cli\u003eSmall Type 0.5 HP to 1 HP: Capacitor start, CSIR, Basic configuration only\u003c\/li\u003e\n\u003cli\u003eLarge Type 1.5 HP to 5 HP: Capacitor start capacitor run, CSCR, Basic or Plus\u003c\/li\u003e\n\u003cli\u003ePlus Configuration: Adds magnetic line contactors matched to the motor rating\u003c\/li\u003e\n\u003cli\u003eEnclosure: Metal casing with protective painted coating, NEMA 3R, indoor or outdoor\u003c\/li\u003e\n\u003cli\u003eConduit Knockouts: Three knockouts. Small Type 1\/2 in and 3\/4 in conduit. Large Type 1\/2 in and 1 in conduit\u003c\/li\u003e\n\u003cli\u003eSmall Type Enclosure Dimensions: 4.9 in by 8.2 in by 2.9 in\u003c\/li\u003e\n\u003cli\u003eLarge Type Enclosure Dimensions: 8.3 in by 9.8 in by 5.9 in\u003c\/li\u003e\n\u003cli\u003eMounting: Vertical, top side up\u003c\/li\u003e\n\u003cli\u003eField Wiring: 14-10 AWG, 75 C copper conductors only, terminal torque 20 lb in\u003c\/li\u003e\n\u003cli\u003eShort Circuit Rating: 5 kA when protected by the fuse class and size listed for the model\u003c\/li\u003e\n\u003cli\u003eCertification: CSA certified to Canadian and US standards, CSA certificate 70000094, project 70047806\u003c\/li\u003e\n\u003cli\u003eStandards: CSA C22.2 No. 14, CSA C22.2 No. 94.2, UL 508, UL 50E\u003c\/li\u003e\n\u003cli\u003eSiting Note: Shade the box from direct sunlight where ambient exceeds 95 F, as heat shortens capacitor life\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRequired starting and protection components for a 3-wire single phase submersible motor\u003c\/li\u003e\n\u003cli\u003eMatched by DAB to each motor horsepower and voltage\u003c\/li\u003e\n\u003cli\u003ePlus versions include a built-in magnetic line contactor, removing the external contactor\u003c\/li\u003e\n\u003cli\u003eIdentical capacitor values between Basic and Plus at every horsepower\u003c\/li\u003e\n\u003cli\u003eNEMA 3R metal enclosure with protective coating for indoor or outdoor mounting\u003c\/li\u003e\n\u003cli\u003eThree knockouts for straightforward conduit entry\u003c\/li\u003e\n\u003cli\u003eBuilt-in overload protector that trips on a shorted capacitor, voltage fault or locked pump\u003c\/li\u003e\n\u003cli\u003eCSA certified to both US and Canadian standards\u003c\/li\u003e\n\u003cli\u003eFull 0.5 HP to 5 HP coverage from one product line\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIdeal Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eResidential drilled well systems with 4 in three wire submersible pumps\u003c\/li\u003e\n\u003cli\u003eAgricultural and livestock water supply\u003c\/li\u003e\n\u003cli\u003eIrrigation wells\u003c\/li\u003e\n\u003cli\u003eReplacing a failed or undersized control box on an existing well\u003c\/li\u003e\n\u003cli\u003eNew submersible pump installations with DAB TESLA 4GG or 4GX motors\u003c\/li\u003e\n\u003cli\u003eWell service contractor truck stock across the common horsepower range\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Valley Milan","offers":[{"title":"0.5 HP - 115V - Basic","offer_id":52945981145399,"sku":"DAB60174729","price":171.0,"currency_code":"USD","in_stock":true},{"title":"0.5 HP - 230V - Basic","offer_id":52945981178167,"sku":"DAB60174730","price":171.0,"currency_code":"USD","in_stock":true},{"title":"0.75 HP - 230V - Basic","offer_id":52945981210935,"sku":"DAB60174731","price":186.0,"currency_code":"USD","in_stock":true},{"title":"1 HP - 230V - Basic","offer_id":52945981243703,"sku":"DAB60174732","price":205.0,"currency_code":"USD","in_stock":true},{"title":"1.5 HP - 230V - Basic","offer_id":52945981276471,"sku":"DAB60174733","price":298.0,"currency_code":"USD","in_stock":true},{"title":"2 HP - 230V - Basic","offer_id":52945981309239,"sku":"DAB60174734","price":447.0,"currency_code":"USD","in_stock":true},{"title":"3 HP - 230V - Basic","offer_id":52945981342007,"sku":"DAB60174735","price":524.0,"currency_code":"USD","in_stock":true},{"title":"5 HP - 230V - Basic","offer_id":52945981374775,"sku":"DAB60174736","price":605.0,"currency_code":"USD","in_stock":true},{"title":"1.5 HP - 230V - Plus","offer_id":52945981407543,"sku":"DAB60174737","price":391.0,"currency_code":"USD","in_stock":true},{"title":"2 HP - 230V - Plus","offer_id":52945981440311,"sku":"DAB60174738","price":542.0,"currency_code":"USD","in_stock":true},{"title":"3 HP - 230V - Plus","offer_id":52945981473079,"sku":"DAB60174739","price":616.0,"currency_code":"USD","in_stock":true},{"title":"5 HP - 230V - Plus","offer_id":52945981505847,"sku":"DAB60184859","price":745.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/0341\/5863\/files\/dab-tesla-4cbus-well-pump-control-box-1.jpg?v=1788482482","url":"https:\/\/www.blacklabelsupply.io\/products\/dab-tesla-4cbus-well-pump-control-box","provider":"BLACK LABEL","version":"1.0","type":"link"}